ac700

AC700 Temposonic® Interface Card

The AC700 Temposonic® card provides multiple digital interfaces for MTS® I, MTS® II, LP and LH Temposonics probes. Through the use of user installable jumpers, the interface card meets all interfacing needs for MTS® linear transducers.

Firmware Features

  • +5vdc regulator installed on board
  • Capable of interrogating transducers > 100ft
  • Heavy duty Entrelec connectors used for high vibration environments
  • Board thickness is .120" to provide for solid non flexing in high g-force environments
  • All firmware soldered directly to board
  • User installable jumpers for configuring the board
  • Board jumpers include 1-8 Recirculations, external/internal interrogation, MTS® I and MTS® II, jumper configuation for MTS® II probes using DPM's
  • Red Power status and Yellow Run status LED's mounted on the board and located on a printed operating/troubleshooting truth table overlay
  • Servo valve connections on board terminals
  • Labeled terminal connections
  • Installation and operation manual provided with each unit
  • Timing selection for probes 0 to 48" and 48" to 170"

Power Requirements

C700 Power Requirements

Voltage Current Tolerance
External + 5V Supplied
+ 15 VDC 50 mA + 14.25 to + 15.75 VDC
- 15 VDC 25 mA - 14.25 to - 15.75 VDC
+ 5 VDC 200 mA + 4.75 to + 5.25 VDC
No External + 5V
+ 15 VDC 275 mA + 14.25 to + 15.75 VDC
- 15 VDC 25 mA - 14.25 to - 15.75 VDC

Tenpsonics Probe Power Requirements

Voltage Current Tolerance
MTS I Probes
+ 15 VDC 5 mA + 14.25 to + 15.75 VDC
- 15 VDC 20 mA - 14.25 to - 15.75 VDC
+ 5 VDC 25 mA + 4.75 to + 5.25 VDC
MTS II Probes
+ 15 VDC 150 mA + 14.25 to + 15.75 VDC
- 15 VDC 100 mA - 14.25 to - 15.75 VDC

Operating Temperature

  • -40 TO 150°F ( -40 to 66°C)