Resaw Systems
Our Systems are Compatible with All Makes and Models of Carriages
Features
- Linebar sets 1 through 16 plus left/right jog
- Four species size tables
- Easy calibration
- Since a PLC is used, customer specified machine control is possible. An example, manual and auto roll sequencing
- Enclosures and consoles are UL inspected
Saw Controls
- Servo Sensor® motion controllers mounted in linebar hydraulic cylinders.
PLC Touch Screen Features
- Run screen displays status of saw axis, real time position, target position, trouble messages, board selected, and many other features
- Board sizes, operational limits, Servo dynamic values, servo limits, etc. are entered through the touch screen display and saved in the PLC battery backup ram.
- Help menus for trouble shooting if necessary are on the touch screen
- Some operational features are displayed on the help screens
- Input/output status is displayed on the I/O screen. Servo Sensor® status is displayed on screen
- Timer entries for roll sequencing
- The run screen will also show a trouble message if a problem occurs with the system
System Hardware Features
- The system control cabinets, operator panel, and j-boxes are pre-wired at the factory
- All cables are labeled and cut pigtails are left at the terminal blocks of each enclosure
- Rewiring of the enclosures is expedited because the colored wires and pairs are left as they were when tested at the factory
- Each enclosure has an identifying placard on the front of it
- The operator console overlay is reverse engraved, to prevent wear and tear over the years of operation
- An interconnect cable diagram is provided as well as an installation/operation manual
- The manual is written to cover most operational procedures and installation requirements
- Resaw control hardware
Operator Panel
- All inputs and outputs within panel are +24VDC
- LED lamps used within the lighted push buttons for longer MBF
- Lighted E-Stop and control power buttons
System Hardware
- The system control cabinets, operator panel, and j-boxes are pre-wired at the factory
- All cables are labeled and cut pigtails are left at the terminal blocks of each enclosure
- Rewiring of the enclosures is expedited because the colored wires and pairs are left as they were when tested at the factory
- Each enclosure has an identifying placard on the front of it
- The operator console overlay is reverse engraved, to prevent wear and tear over the years of operation
- An interconnect cable diagram is provided as well as an installation/operation manual
- The manual is written to cover most operational procedures and installation requirements